      Home 熱式質量流量計

      Model Number

      Specifications

      Power Requirement

      Features

      Steel-Mass 640S

      640s.jpg

      Immersible Thermal Gas Mass Flow Meter

      *Gas: Most Gases

      *Max pressure:

      Compression fittings:500psig

      1 inch 150lb flange:185psig

      Low pressure Hop tap:150 psig

      High pressure Hot tap:1000 psig

      *Temperature:

      Gas:-40~177),

      Ambient:-40~50。

      High:400(air only)

      *Response time: one second.

      *Accuracy: ±1% of reading+0.5% of F.S

      *Repeatability: ±0.2% of F.S

      18~30 VDC

      100~240 VAC,

      50/60 Hz

      *Patented  Dry-Sensor technology eliminates sensor drift.

      *Low and High pressure hot taps
        available.

      *With Alphanumeric 2 x 12 digital backlit LCD(Optional)

      *Hazardous-Area Location Enclosure(IP66) or NEMA4X(IP65).Both are powder-coated cast aluminum.

      Output signal

      0-5 VDC

      0-10 VDC

      4-20 mA

      Model Number

      Measurement

      Power Requirement

      Features

      Flat-Trak 780S

      780s.jpg

      Smart In-Line Thermal Gas Mass Flow Meter with Flow Conditioner.

      *Gas: Most Gases.

      *Max pressure:

      Compression fittings:500psig

      1 inch 150lb flange:185psig

      Low pressure Hop tap:150 psig

      High pressure Hot tap:1000 psig

      *Temperature:

      Gas:40~177

      Ambient:-40~50

      *Response time: onesecond.

      *Accuracy: ±1% of reading+0.5% of F.S

      *Repeatability: ±0.2% of F.S

      18~30 VDC

      100~240 VAC,

      50/60 Hz

      *Built-in flow conditioner which eliminates velocity-profile distortions caused by upstream disturbances.

      *Patented  Dry-Sensor technology eliminates sensor drift.

      *With Alphanumeric 2 x 12 digital backlit LCD(Optional)

      *Hazardous-Area Location Enclosure(IP66) or NEMA4X(IP65).Both are powder-coated cast aluminum.

      Output signal

      0-5 VDC

      0-10 VDC

      4-20 mA

      Model Number

      Measurement

      Power Requirement

      Features

      780S-UHP

       780suhp.jpg

      Smart Ultra High Purity Thermal Gas Mass Flow Meter.

      *Gas: Argon,Helium,Hydrogen,

      Nitrogen,Oxygen…etc.

      *Max pressure: 500 psig

      *Temperature: 0-50。

      *Response time: onesecond.

      *Accuracy: ±1% of reading+0.5% of F.S

      *Repeatability: ±0.2% of F.S

      *Temperature:

      Gas:40~120

      Ambient:-40~50。

      18~30 VDC

      100~240 VAC,

      50/60 Hz

      *The Ultra High Purity meters are constructed of 316L electro-polished, stainless steel with a 7-10 Ra interior finish.

      *Built-in flow conditioner which eliminates velocity-profile distortions caused by upstream disturbances. With 2 x12 digital display.

      *Hazardous-Area Location Enclosure(IP66) or NEMA4X(IP65).Both are powder-coated cast aluminum.

      Output signal

      0-5 VDC

      0-10 VDC

      4-20 mA

      Model Number

      Measurement

      Power Requirement

      Features

      Multi-Trak 670S

      670.jpg

      High-Performance

      Multi-Point Mass Flow

      Meter System For Large

      Duts & Stacks.

      *Gas: Most gases.

      *Max pressure:

      Compression fittings:500psig.

      1 inch 150lb flange:185psig.

      Low pressure Hop tap:150 psig.

      High pressure Hot tap:1000psig.

      *Temperature:

      Gas:-40~177.

      Ambient:-40~50.

      High:400(air only).

      *Response time: one second.

      *Accuracy: ±1.5% of F.S.

      *Repeatability: ±0.5% of F.S.

      18-30 VDC

      *Unique multiple transmitter approach allows individual points to be removed for service or repair without shutting down the system and allows users the ability to compensate for swirl.

      *Patented  Dry-Sensor technology eliminates sensor drift.

       

      Output signal

      4-20 mA

      Model Number

      Measurement

      Power Requirement

      Features

      Flast-Flo 620S

      620s.jpg

      Fast Response High Performance Immersible Thermal Gas Mass Flow Meter.

      *Gas: Most non-corrosive gases.

      *Max pressure: 120 psig.

      *Temperature:

      Gas:-40~80.

      Ambient:-40~50.

      *Response time: 200 ms.

      *Accuracy: ±1.% of F.S.

      *Repeatability: ±0.2% of F.S.

      18~30 VDC

      *Fast response flow meter ideal for gas mass flow measurement applications.

      *Minimal flow blockage and low pressure drop.

      *Optional 2 x 12 backlit LCD display.

      Output Signal

      0-5 VDC

      0-10 VDC

      4-20 mA

      Model Number

      Measurement

      Power Requirement

      Features

      Fast-Trak 730730s.jpg

      Fast Response Ultra Stable Mass Flow Meter

      *Gas: Most non-combustible, 
        non-corrosive.

      *Max pressure:150psi.

      *Temperature:

      Gas:-10~80.

      Ambient:0~50.

      *Response time: 200 ms.

      *Accuracy: ±1% of F.S.

      *Repeatability: ±0.2 %of F.S.

      *Flow Range: 0.03~50scfm.

      15-18 VDC

      24 VDC

      *Ultra stable Glass/Ceramic flow
        sensor.

      *Low insertion pressure loss.

      *200 millisecond response to changes in flow rate.

      *Enclosure: Anodized aluminum 
         NEMA 2

      Output Signal

      0-5 Vdc

      4-20 mA

      Model Number

      Measurement

      Power Requirement

      Features

      Boiler-Trak

      boiler.jpg

      Natural Gas & Propane Immersible Thermal Gas Mass Flow Meter

      *Gas: Natural gas,Propane, Methane.

      *Max pressure: 0~120psig.

      *Temperature:

      Gas: -40~80.

      Ambient:0~50.

      *Response time: 200 ms.

      *Accuracy: ±1% of F.S.

      *Repeatability: ±0.2 %of F.S.

      15~18 VDC

      *Fast response flow meter optimized for natural gas or propane measurement applications.

      *2x12 backlit LCD display totalizer values along with instantaneous flow display.

      Output Signal

      0-5 VDC

      4-20 mA

       

       