      Home 超音波質量流量計

      Model Number

      Specifications

      Power Supply

      Features

      Innova-Sonic 205

      205c.jpg

      Clamp on type.

      Ultrasonic Transit-Time

      Clamp on & Insertion Flow Meter.

      *Fluid:liquids with a small quantity of air bubbles or suspended solids.

      *Temperature:

      Transmitter:-40~60.

      transducer:

      -Clamp on: -40~80.

      (High temp.: -40~170)

      -Insertion: -40~80.

      (High temp.: -40~150)

      *Accuracy:±0.5 % of reading.

      *Repeatability: ±0.5% of reading.

      *Pipe Size:1”~200”(25mm~5m).

      *Flow Range:0~±40 ft/s(0~±12 m/s).

      90~250 VAC, 48~63 Hz and 10~36 VDC.

      *Clamp on sensor require no pipe cutting or process interruption and no plant shut-down.

      *Available with standard insertion transducers or small(0.75” diameter) insertion transducers for pipes smaller than 16”(DN400)

      *Offers low power consumption, high reliability, and outstanding applicability.

      205i.jpg Insertion type.

      Output signal

      0/4~20 mA

      Pulse

      Relay

      RS-232

      RS-485

      Model Number

      Specifications

      Power Supply

      Features

      205 Thermal Energy

      205s.jpg

      Ultrasonic Thermal Energy Meter.

      *Fluid: For liquid heating and cooling applications.

      *Temperature:

      Transmitter:-40~60.

      transducer:

      -Clamp on: -40~80.

      (High temp.: -40~170)

      -Insertion: -40~80.

      (High temp.: -40~150)

      *Accuracy:±0.5% of reading.

      *Repeatability: ±0.5% of reading.

      *Pipe Size:1”~200”(25mm~5m).

      *Flow Range:0~±40 ft/s(0~±12 m/s).

      90~250 VAC, 48~63 Hz and 10~36 VDC

      *Measurement of energy rate and totalized energy consumption.

      *Clamp on sensor mean no pipe break or process interruption and offer low installation effort and costs.

      *Suitable for virtually any liquid heating and cooling application including HVAC, office buildings, large condominium or apartment developments, thermal solar heating and geothermal applications.

      *Includes two PT100 resistance temperature detectors (RTD’S) for measuring inlet and outlet temperature.

      Output signal

      0/4~20 mA

      Pulse:

      0~9999 Hz, OCT

      Relay: SPST

      Model Number

      Specifications

      Power Supply

      Features

      Innova-Sonic 206

       206.jpg

      In-Line Transit-Time Ultrasonic Flow Meter

      *Fluid: liquids with a small quantity of air bubbles or suspended solids.

      *Temperature: Fluid:-40~80.

      *Flow Range:0 ~ 23ft/s(0 ~ 7 m/s).

      *Pipe Size:1”~10”(25mm~250mm).

      *Accuracy:±0.5% of reading.

      *Repeatability: ±0.2% of reading.

      90~250 VAC, 48~63 Hz and 12~36 VDC.

      *Ultra-precise patented time measurement technology measures the transit-time accurately between the upstream and downstream transducers.

      *Power coated Carbon Steel(150# ANSI or DN PN10)

      *Our patented ultra precise PicoFlyTM measurement technology allow ultrasonic transit time of flight samples to be measured in picoseconds 10-12 for superb resolution and tremendous low flow detection rather than typical nanoseconds 10-9.

      Output signal

      0/4~20 mA.

      Pulse.

      Relay: SPST.

      RS-232.

      Model Number

      Specifications

      Power Supply

      Features

      Innova-Sonic 210

       210.jpg

      Portable Ultrasonic Flow meter with Bluetooth? Wireless.

      *Fluid: liquids with a small quantity of air bubbles or suspended solids.

      *Temperature:

      Transmitter:-40~60

      Transducer:-40~80

      *Flow Range: 0~±40 ft/s(0~±12 m/s)

      *Pipe Size:1”~200”(25mm~5m

      *Accuracy:±0.5% of reading.

      *Repeatability: ±0.5% of reading.

       

      12 VDC(10~36 VDC) Battery power(main and spare batter are respectively 8 hr).

      *Palm? TX PDA interface with Bluetooth? wireless.

      *Clamp on sensor require no pipe cutting or process interruption and no plant shut-down.

      *Magnetic sensor clamping fixture with slip-scale gage.

      *Battery power supply with battery recharge port.(including spare battery)

      *Hygienic measurement, no risk of contamination, suitable for ultra clean liquids.

      Output signal

      4-20 mA.

      Pulse.

      Relay.

       